C 33-224 / C33-225 are MV cable. It is Stranded Bare or Tinned Copper Conductor, XLPE Insulation, Copper Tape Shielded Airport Lighting Cable
C 33-224 / C33-225 cables are used as airfield lighting equipment primary cables for the series circuit connecting the Constant Current Regulators and the isolating transformers, and between the isolating transformers.
C33-224
C33-225
Conductor: Stranded bare or tinned copper conductor.
Inner Semi-Conductor: Extruded semi-conducting compound.
Insulation: XLPE/MDPE
Outer Semi-Conductor: Extruded semi-conducting compound.
Shield: Copper tape shield or Copper wire shield.
Sheath: XLPE/PVC/HFFR/CR
Rated Voltage Uo/U (Um) | 3.6/6(7.2kV); 6/10 (12kV) |
Maximum Conductor Temperature | 90℃ |
Short Circuit Temperature | 250℃ |
Operating Temperatures | -20℃~+70℃ |
Minimum Bending Radius | static: 10×OD; dynamic: 20×OD |
Impacted Resistant | Yes |
Weather Resistant | Yes |
Construction | No. of Strand | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight |
No. ×mm² | - | mm | mm | mm | kg/km |
1×6 | 7 | 2.7 | 1.4 | 12.5 | 198 |
Construction | No. of Strand | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight |
No. ×mm² | - | mm | mm | mm | kg/km |
1×6 | 7 | 3.6 | 1.6 | 14.7 | 250 |